Technical Helpdesk
+49(0)1805 - 85 85 11*
(Mo-Fr 8-17h)
ShoppingCart
0 Article
MyAccount
|
Login
Products
Calibration-Service
Support & Contact
Downloads
Company
References
Search
Products
Pressure
Humidity
Brightness and Motion
Air Quality
Meteorology
Flow
Temp. Transducer
Temperature Probes
Thermocouples
Thermostats
Contacting thermosat
Anti-freeze thermostat
Duct thermostat
Capillary thermostat
Room thermostat
Safety limiter
Actuator
Shipment
Shipping and Handling
Terms of Payment
comfortable per invoice after receipt of goods
(on payment target)
economical per prepayment
(less 3% discount)
easy per cash on delivery
(plus COD charge)
Delivery and Payment Terms
Attention
: JavaScript is disabled on your browser! To be able to see all products JavaScript must be enabled.
How it works?
You are here:
Thermostats
>
Duct thermostat
>
TRK/N
Print page
Duct Thermostat with Change-Over Contact
The thermostat TRK/N was planed as a minimal- or maximal thermostat for the delivery air control and ventilator controller in ventilation and air-conditioning. The canal thermostat serves as an overheating protection thermostat for electric heater coils and directly fired air heater in the oil and gas-fuelled operation.
[+] Zoom
Request Offer
Technical Specifications
Data Sheet
Accessories (1)
Rating:
15 (8) A, 24 - 250 V~, at 24 V~ min. 150 mA
Contact:
1 micro switch as a potential free change-over contact (change-over switch)
Sensor:
Fluid sensor of Cu, activ on total lenght
Enclosure:
IP40
Protection class:
I
Ambient temperature:
-15°C...+80°C
Max. sensor temperature:
+200°C
Colour:
Grey
Type testing:
TÜV according to DIN 3440 (Reg.-Nr. STB 65901 for warm air boiler according to DIN 4794)
Type identification:
TW = Temperature guard, STB = safety temperature limiter, TB = Temperatur limiter
Intrinsic safety (ES):
At lost of the sensor medium (sensor broken) the burner will be stopped now
Insulation for cold (KÄ):
With the cold screw, it is possible to justified all types, that the measurment tools stop the burner, at temperatures less than -15°C. The reactivation goes only by hand (manual) and temperatures higher than approx -5°C.
Over heating protection (ÜS):
The type saves for uncontrolled over heating caused by for example heat accumulation. At obtain the temperature of +220°C the safety plumb is smelting inside the sensor an the console stopped the burner. The burner is not resetable. The console is unusable.
Duct Thermostat with Change-Over Contact
Electro-thermal Actuator TS+
(Commodity Group 2)
available from stock |
Into the shopping cart |
Request Offer |
Check Delivery Time
Article No.
Control Range
Differential Gap
Type
Length
Equipment
List price
(plus VAT)
Quantity
TRK/N-10
-25...+65°C
1,5 K
TW
350 mm
-
91,20 EUR
TRK/N-20
+20...+100°C
8...30 K adjustable
TW
350 mm
ES/KÄ
105,60 EUR
TRK/N-30
+20...+100°C
Hand return
STB
350 mm
ES/KÄ
92,80 EUR
TRK/N-40
+20...+100°C
Hand return
STB
350 mm
ES/KÄ/ÜH
92,80 EUR
TRK/N-50
+20...+100°C
Hand return
STB
1250 mm
ES/KÄ
99,20 EUR
TRK/N-60
+60...+140°C
8...30 K adjustable
TW
350 mm
-
105,60 EUR
TRK/N-70
+60...+140°C
Hand return
TB
350 mm
-
91,20 EUR
(
Please consider:
Not listed article types can be ordered separately on
request
.)